Fresh-food section too cold

What is going on

Fresh-food too cold. Usually the airflow control. It's open too far, stuck, or broken.

Likely causes

  • Airflow control (damper) set at coldest
  • Control stuck open or obstructed
  • Broken airflow control
  • Broken airflow heater

Check in this order

  1. Turn the control warmer and give it time.
  2. Look for obstruction in the damper, such as ice or food packaging.
  3. Check the damper moves freely by hand with the unit unplugged.
  4. Test the airflow heater for continuity and replace it if open.
  5. Replace the control if it won't respond.
  6. Watch the fresh-food temperature for a few hours afterward.

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.