Freezer too cold
What is going on
Freezer running too cold. Control problem in most cases.
Likely causes
- Control set too cold
- Sensing bulb not clamped to the evaporator, so it reads wrong because it is not in contact with the coil
- Broken control that never opens
Check in this order
- Set the control warmer and see whether the compressor cycles off
- Check the sensing bulb is tight against the evaporator, since a loose bulb makes the unit run longer
- Tighten the clamp or reposition the bulb
- Test the control if it stays closed at a warmer setting, replace it
- Check freezer temperature with a thermometer after a few hours
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.