All brands · Refrigeration troubleshooting

Doesn't fill with water

What is going on

The ice maker cycles but the mold never fills with water. The fill step is skipped or no water is arriving. Start at the water supply, then check the control side.

Likely causes

  • No or low water flow from a closed supply valve, frozen line or clogged strainer
  • Signal arm stuck up, so the control skips the fill
  • Motor dead, so the cycle never reaches the fill step
  • Water valve solenoid open or without power

Check in this order

  1. Check the supply open the shutoff valve and look for flow, because a closed or frozen line gives the same symptom.
  2. Clean the inlet strainer because sediment blocks flow.
  3. Clear the signal arm so it moves freely and is not held up by ice.
  4. Check the motor for voltage and operation with the unit unplugged for resistance checks.
  5. Check the water valve for voltage during the fill step.
  6. Run a cycle and watch for water entering the mold.
  7. Replace the valve or motor if power is present and nothing happens.

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.