Cubes too small
What is going on
Cubes coming out small. Water isn't filling the mold properly. Check level, supply and the water valve switch. Short fill means small cubes every time.
Likely causes
- Mold not level, so water pools to one side
- Low water delivery from a blocked strainer or weak supply pressure
- Faulty water-valve switch cutting the fill short
- Partly closed shutoff or kinked supply line
Check in this order
- Level the mold.
- Check water supply pressure and clean the inlet strainer.
- Check the shutoff valve is fully open and the line is not kinked.
- With the power off, check the water-valve switch contacts.
- Run a cycle and watch the fill time.
- Measure cube size over a couple of cycles.
- Replace the valve or switch if the fill stays short.
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.