All brands · Heat pump troubleshooting

Water-source: coil freezing

What is going on

On a water-source heat pump, a freezing coil usually means the water side isn't up to the job. In cold climates the loop needs glycol, and an open loop needs enough clean water flowing. Check this before blaming the refrigerant side.

Likely causes

  • No glycol in the loop in a cold climate
  • Open-loop water quantity too low
  • Open-loop water quality poor

Check in this order

  1. Check that the loop has glycol in a cold climate
  2. Check the freeze point of the loop fluid
  3. For open loop, measure the water flow
  4. Check water quality and strainers
  5. Watch the coil temperature
  6. Call a licensed tech to review the loop

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.