Extremely high head pressure in heating (dual fuel)
What is going on
Extremely high head pressure in heating on a dual fuel system is a red flag. Confirm that the heat pump and the furnace aren't running together. Running both can push pressures dangerously high, so shut the system down and check before restarting. Refrigerant work is for a licensed tech.
Likely causes
- Furnace burner running while the compressor is running
- Interlock between the heat pump and furnace missing or failed
Check in this order
- Shut the system down and check the gauges before restarting
- Confirm the furnace and compressor are not running together
- Check the interlock wiring and the thermostat setup
- Verify the lockout between heat pump and furnace
- Restart and watch the head pressure
- Call a licensed tech to check the charge
More heat pump guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail
- Auxiliary heat indicator light is on
- Excess ice on outdoor coil
- Insufficient heat in cold weather
- Liquid slugging / compressor damage in heating
- No mode change / wrong mode
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.