All brands · Heat pump troubleshooting

TXV bulb/diaphragm failure

What is going on

A failed TXV bulb or diaphragm on a heat pump is a mismatch story more often than not. Someone puts a straight air conditioning TXV on a heat pump, or the bulb sits where discharge gas cooks it. Either way the valve loses its charge and quits controlling.

Likely causes

  • Non-MOP (AC) TXV installed on a heat pump
  • Bulb overheated by discharge gas

Check in this order

  1. Confirm the TXV is rated for heat pump duty
  2. Check the bulb location and mounting
  3. Inspect the bulb and capillary for damage
  4. Check superheat, which needs a licensed tech
  5. Replace with the correct heat pump TXV
  6. Make sure the bulb is clamped and insulated properly

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.