All brands · Heat pump troubleshooting

Subcooling too high

What is going on

Subcooling reading high on a heat pump. Liquid is backing up in the condenser, so the unit is carrying too much refrigerant. Check the number against the target on the data plate before acting.

Likely causes

  • Overcharge, too much refrigerant in the system

Check in this order

  1. Confirm the reading with clean coils, normal airflow and stable operating conditions
  2. Recover the excess refrigerant down to the target subcooling. Recovery must be done by a licensed technician
  3. Check head pressure and amp draw afterwards to see they are back to normal
  4. Re-check subcooling once the system settles

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.