Poor heating but OK cooling (or vice-versa)
What is going on
A heat pump that heats fine but cools poorly, or the other way around, points to the metering device on one side of the circuit. A piston-type device has to meter in one direction and slide free in the other, so a problem in either direction shows up in only one mode. Measure carefully in each mode and make no assumptions. Refrigerant work should be done by a licensed technician.
Likely causes
- Piston not seating in the metering direction
- Piston not sliding free in the bypass direction
- Check valve bypass stuck
Check in this order
- Read pressures in each mode and compare them
- Inspect the piston condition
- Check the check valve for sticking
- Recover refrigerant before opening the circuit, licensed technician only
- Confirm both heating and cooling performance after repairs
More heat pump guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail
- Auxiliary heat indicator light is on
- Excess ice on outdoor coil
- Extremely high head pressure in heating (dual fuel)
- Insufficient heat in cold weather
- Liquid slugging / compressor damage in heating
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.