All brands · Heat pump troubleshooting

Odour at registers (dirty sock)

What is going on

Dirty sock smell at the registers when the heat pump runs. That's mold or bacteria growth on the indoor coil. Worst at startup when the coil is wet.

Likely causes

  • Mold or bacteria growing on a wet indoor coil
  • Dirty drain pan holding water
  • Dirty filter feeding the growth
  • Poor drain slope or clogged condensate line

Check in this order

  1. Turn power off and inspect the indoor coil.
  2. Clean the coil with an approved coil cleaner.
  3. Clean the drain pan and check the drain flows.
  4. Check and replace the filter.
  5. Consider a UV lamp.
  6. Run the system and confirm the smell is gone.

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.