All brands · General troubleshooting

Trouble light on / ozone smell / dusty rooms / constant arcing

What is going on

Trouble light on, ozone smell, dusty rooms or constant arcing and snapping on an electronic air cleaner. What I usually find is dirty or wet cells overloading the unit, especially after carpet install, construction dust or leaky ducts. Power it down first, because the power pack carries high voltage.

Likely causes

  • Dirty or wet cells
  • Electrical fault in the rectifier, power pack caps, ionizing wires or insulators
  • Bent plates shorting the cell
  • Overload from carpet, construction dust or leaky ducts

Check in this order

  1. Cut power, then clean the cells and screens and let them dry fully, using the dry switch or running the blower
  2. Check that the doors are closed, the switch and fuses, and the meter or indicator codes
  3. Use a high-voltage probe to test the power pack
  4. Replace broken wires and insulators
  5. Straighten bent plates
  6. Find and seal what is dumping dust into the system

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.