Condensation on windows/walls in cold weather
What is going on
Water beading or running on windows and walls in cold weather tells you the indoor humidity is higher than the outdoor temperature can handle. Cold glass drops the air against it below its dew point. Before adjusting anything, confirm what the humidistat is set to and what the outdoor temperature is today, because moisture left on framing can lead to mold and rot.
Likely causes
- Indoor relative humidity set too high for the outdoor temperature
Check in this order
- Read the indoor relative humidity with a reliable hygrometer, not just the control dial
- Check the outdoor temperature today
- Look up the recommended indoor humidity in the A26 table and reset the humidistat to match
- Lower the setting further when it turns colder, and recheck after a day or two
- Wipe down wet frames and sills and watch for mold on the framing
- If the humidity still reads high, look at other moisture sources and ventilation
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.