Condensation on windows/walls, peeling paint
What is going on
Moisture on windows and walls, with paint peeling nearby. Indoor humidity is meeting a surface that is colder than the dew point.
Likely causes
- High indoor RH against a cold surface, check the dew point table because the same RH condenses at a higher temperature on colder glass
- Missing vapour barrier letting moisture into wall cavities
- Bath and kitchen moisture with no exhaust
Check in this order
- Measure indoor RH and surface temperature, then compare to the dew point table
- Lower the RH with a dehumidifier and run the bath and kitchen exhaust fans
- Raise the surface temperature with better insulation or storm windows
- Install or repair the vapour barrier on the warm side of the wall
- Recheck for condensation after a cold snap
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.