All brands · General troubleshooting
Stale/stuffy, fatigue, headaches
What is going on
Stale, stuffy air with fatigue and headaches. Classic low-ventilation house. CO2 builds up, the envelope is tight and there's no fresh air coming in.
Likely causes
- Poor ventilation, high CO₂ is the marker
- Tight envelope with no makeup air path
- Dirty filters cutting airflow
Check in this order
- Add an HRV or ERV, or a damper-controlled fresh-air duct
- Verify the ventilation rate, cfm per person or 3+ ACH
- Replace the filters
- Take a CO₂ reading before and after to prove the fix
- If any combustion appliance is in the house, have it checked for safe draft
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.