Smart Air Quality Monitor response to poor indoor air quality
What is going on
When the monitor detects poor indoor air quality it passes this to the thermostat, which tries to clean the air. The method depends on the IAQ equipment installed. The thermostat only starts showing monitor data after the first blower, cooling or heating demand. Until then the monitor shows it is calculating.
Check in this order
- With no IAQ equipment, the thermostat runs the indoor blower to circulate air.
- With a high efficiency filter, the thermostat runs the blower to pass air through the filter cabinet.
- With Pure Air, the thermostat runs the Pure Air system to circulate air through it.
- With an ERV or HRV, the thermostat compares outdoor and indoor air quality. If outdoor air is better it brings in fresh air. If outdoor air is poorer it runs the indoor blower on indoor air.
Applies to: Lennox Smart Air Quality Monitor with S40 Smart Thermostat
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Lennox S40 Smart Thermostat User Guide, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.