Lennox · General troubleshooting
Ambient lockout shown on home screen
What is going on
The outdoor temperature is outside the balance point settings. Below the low balance point, heat pump heating is locked out and only auxiliary heat (electric or gas) runs. Above the high balance point, auxiliary heat is not allowed and only heat pump heating runs. The dealer sets both balance points. The low point defaults to 25°F (-4.0°C).
Likely causes
- Outdoor temperature is below the low balance point
- Outdoor temperature is above the high balance point
Check in this order
- Compare the outdoor temperature with the balance point settings in the thermostat.
- If the lockout is not expected, have the dealer check and adjust the low and high balance points.
Applies to: Lennox L40 Smart Thermostat with heat pump
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Lennox Home (L40) User Guide, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.