Negative pressure / drafts / spillage

What is going on

Negative pressure in the house. Combustion appliance competes with fans, dryer and exhaust for air. Result is drafts, backdrafting and spillage. Treat spillage as a CO risk until proven otherwise.

Likely causes

  • Combustion appliance drawing house air
  • Exhaust fans, dryer and range hood pulling more air out than comes in
  • No makeup air supply

Check in this order

  1. Test for spillage at the draft hood or flue with all exhaust fans and the dryer running
  2. Test the room for CO
  3. Check the flue and chimney for blockage
  4. Add a makeup air unit, either a return-duct damper type or a mechanical-room type
  5. Retest draft and spillage after the install
  6. Have a licensed gas or oil tech do the final verification

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.