All brands · Electrical troubleshooting
No power / low voltage
What is going on
No power or low voltage at the load. Meter first, guess later. Work back from the load toward the source until you find where the voltage drops.
Likely causes
- Open sequencer
- Open thermostat or open control circuit
- Low line voltage at the supply
- Low transformer output
Check in this order
- Meter the line voltage at the panel and at the unit
- Meter the transformer secondary; compare to the rated 24 volts
- Check the thermostat for an open and the wiring for loose connections
- Check the sequencer for a closed contact on a heat call
- Look for loose or burned terminals and fix with power off
- Have the utility or an electrician look at it if the supply itself is low
More electrical guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.