All brands · Electrical troubleshooting

No heat — line-voltage stat

What is going on

No heat from a line-voltage thermostat circuit, such as baseboard. Line voltage is live at the stat, so go slowly and verify before touching it. Open the breaker first.

Likely causes

  • Tripped breaker
  • Thermostat contacts failed open
  • Wiring problem upstream of the thermostat

Check in this order

  1. Check the breaker, and reset only if it's clearly safe
  2. Open the breaker and verify the circuit is dead before pulling the stat
  3. Pull the stat and set the meter above the expected line voltage range
  4. Restore power carefully and read for line voltage across the open terminals
  5. If line voltage shows across the open terminals, the stat is bad, so replace it with a line-voltage type after opening the breaker and verifying it dead
  6. No voltage at the stat means a wiring problem, call an electrician

More electrical guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.