House too humid

What is going on

A house that feels too humid with an electric furnace is often a tight envelope. A tight house holds moisture and, when fuel-burning appliances are present, may not get enough combustion air. Before assuming it is only comfort, confirm that any combustion appliance in the building has adequate draft and air and that CO alarms are working.

Likely causes

  • Tight building envelope that traps moisture
  • No path for combustion draft or makeup air
  • No mechanical ventilation

Check in this order

  1. Check indoor humidity with a hygrometer and note where moisture shows up
  2. Look for condensation on windows and cold surfaces
  3. Check any fuel-burning appliance for proper draft and combustion air
  4. Consider adding an HRV or ERV to bring in fresh air and remove moisture
  5. Add dehumidification if ventilation alone does not control it
  6. Confirm CO alarms are installed and working

More electrical guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.