Wiring the 0-10 V input extension module
What is going on
Module powered from 120 V / 60 Hz, with a 0 to 10 V input, KM-BUS link to the control unit, a zero-volt contact and a T 250 mA fuse.
Check in this order
- Connect the 120 V / 60 Hz supply, with a mains disconnect if required.
- Connect the 0 to 10 V signal to the VF input.
- Connect the KM-BUS link from the module to the control unit.
- Connect the zero-volt contact.
- Set the DIP switches as shown in the DIP switch table.
Applies to: 0-10 V input extension module
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 200 KW2 service instructions, p. 82. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.