Viessmann · Boiler troubleshooting
Wall mounting the boiler bracket and CombiPLUS
What is going on
Mount the boiler bracket and CombiPLUS securely; loose mounting is a severe safety hazard.
Check in this order
- Brick or concrete wall drill 10 mm (3/8 in) holes using the supplied templates, align the bracket and fix with supplied screws and plastic anchors.
- Wood studs drill 3/16 in pilot holes at the center of each stud and secure with bolts.
- Metal studs drill pilot holes at the center of each stud and fit suitable fasteners (not supplied).
- Check that both the boiler bracket and CombiPLUS are tight and secure before proceeding.
Applies to: Vitodens 100-W WB1B with CombiPLUS
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 100-W, WB1B CombiPlus Installation & Service, p. 15-16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.