Viessmann · Boiler troubleshooting
Vertical piping installation (boiler connections)
What is going on
Connect the water and DHW pipes from the top of the boiler, then secure the bottom connections and gas line.
Check in this order
- Fit the O-rings over the male boiler fittings and check they sit in the groove.
- Slide the insulation sleeve over the DHW pipe.
- Pass the pipes through the top cutouts of the boiler.
- Line up the pipes with the boiler fittings and push from the top until snug.
- Secure the pipe ends into the correct restraining rings.
- Fit the supplied locking clips over the bottom boiler connection and pipes.
- Remove the cap from the factory-installed gas line.
- Install the supplied tees, drain valves and gas valve as shown in the manual.
- Fit security clips to the DHW pipe retaining clips.
Applies to: Vitodens 222-F, B2TB vertical piping
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 222-F, B2TB installation instructions, p. 24-25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.