Viessmann · Boiler troubleshooting

Venting through an insulated chase or masonry flue

Vitocrossal 200 CI2

What is going on

Vent material may extend beyond the outside wall only inside an enclosed, insulated, waterproof chase for outdoor use. Space around a chimney liner or existing masonry flue must not be used as combustion air supply. A separate air intake can run in that space if the vent is approved for zero clearance.

Check in this order

  1. Build an enclosed, insulated, waterproof chase if vent runs outdoors beyond the wall.
  2. Do not draw combustion air from the space around a chimney liner or masonry flue.
  3. Use a separate combustion air intake pipe run beside the vent only if the vent is approved for zero clearance.

Applies to: Vitocrossal 200 CI2 vent routing

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocrossal 200 CI2 Installation Instructions, p. 53. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.