Venting choice in damp or salty coastal areas

Vitocrossal 300 CA3B Dual Fuel

What is going on

Metal casing and fan housing corrode faster near sea spray and humid air. In these locations, do not use a direct vent system that draws outdoor air. Use a room air dependent vent system so the boiler takes in drier indoor air.

Likely causes

  • Chloride from sea spray combined with high humidity attacks exposed metal

Check in this order

  1. Confirm the site is damp or salty coastal.
  2. Select a room air dependent venting system instead of direct vent.
  3. Make sure the mechanical room has adequate combustion air supply.

Applies to: Installations in marine environments

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocrossal 300 CA3B Dual Fuel installation manual, p. 49. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.