Viessmann · Boiler troubleshooting
There is no DHW
What is going on
Domestic hot water is not being supplied.
Likely causes
- Heating system is off.
- Control unit is set incorrectly.
- DHW heating is not enabled.
- DHW is being heated by the solar thermal system.
- No fuel reaching the boiler.
- Fault displayed.
- Emissions test switch in test position.
Check in this order
- Switch on the ON/OFF switch on the control units, the mains isolator (if fitted) and the MCB.
- Check operating program, DHW temperature, DHW time program and time.
- Check the solar control unit settings if solar heats the DHW, and correct them if needed.
- Check fuel supply and open the gas shut-off valve if needed.
- If a fault is displayed, acknowledge it and notify the heating contractor if necessary.
- Set the emissions test switch back to its normal position if it is in test position.
Applies to: Vitocrossal 300 CA3B Dual Fuel boiler with DHW
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocrossal 300 Dual Fuel Operating Instructions, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.