System layout: multizone with low loss header
What is going on
Zones are controlled by thermostats, and DHW has priority from the Versatronik pump module. The boiler has a dedicated pump connected to the Vitodens pump module.
Check in this order
- Connect the boiler pump to the Vitodens pump module.
- Connect the boiler pump signal to the Versatronik 10.WB1.
- Connect the DHW demand from an aquastat or set-point control to the Versatronik 10.WB1.
- Wire each zone thermostat to its zone controller as required by the system.
Applies to: Multizone systems with low loss header
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Versatronik 10.WB1 installation manual, p. 15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.