Viessmann · Boiler troubleshooting
System layout: boiler with low loss header
What is going on
Boiler pump is connected to the boiler pump module. The Versatronik runs the space heating pump and DHW pump and receives the DHW demand and the boiler pump signal. The optional Versatronik Como OT can be used for outdoor reset.
Check in this order
- Connect the boiler pump to the boiler pump module.
- Connect the space heating pump output to the Versatronik 10.WB1.
- Connect the DHW pump output to the Versatronik 10.WB1.
- Connect the DHW demand from an aquastat or set-point control to the Versatronik 10.WB1.
- Connect the boiler pump output signal to the Versatronik 10.WB1.
- Connect the room thermostat only when the Versatronik Como OT is not used.
Applies to: Boiler with low loss header
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Versatronik 10.WB1 installation manual, p. 12. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.