Viessmann · Boiler troubleshooting

System layout 8: DHW plus three zone circuits with low-loss header

Vitodens 200-W B2HA/B2HB

What is going on

Multiple Vitodens 200-W boilers with a low-loss header feeding three zone circuits through a thermostat-controlled zone arrangement, using the AM1 extension module for zones 2 and 3. Zone 1 uses boiler output 157.

Check in this order

  1. Use a low-loss header; it is strongly recommended.
  2. Connect the DHW pump to output 21 and the boiler pump to output 20.
  3. Wire the zone 1 circuit to output 157.
  4. Install the AM1 extension module and wire zone circuits 2 and 3 to its outputs A1 and A2.
  5. Connect the zone thermostats as dry contacts.
  6. Connect the outdoor sensor, DHW sensor and supply temperature sensor.

Applies to: Multi-boiler with three zone circuits plus DHW

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB installation instructions, p. 40. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.