Viessmann · Boiler troubleshooting

System Layout 7: direct radiator circuit plus system-separated underfloor circuit

Vitodens 200-W

What is going on

Vitodens 200-W B2HB with a direct radiator circuit and an underfloor circuit with system separation. The boiler pump 20 supplies the radiator circuit and the plate heat exchanger.

Check in this order

  1. Keep total circuit flow below the boiler maximum on page 31.
  2. Use a low-loss header if flow exceeds page 31 values or is unknown.
  3. Make sure the plate heat exchanger secondary pressure drop is less than or equal to the 3-way mixing valve pressure drop.
  4. Install the mixing valve accessory kit and mixing valve temperature sensor.
  5. Pipe the DHW circulating pump Q into the boiler.

Applies to: Vitodens 200-W B2HB

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB 45, 57, 160, 199 Installation Instructions, p. 39. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.