Viessmann · Boiler troubleshooting
System Layout 6: radiator circuit plus two underfloor mixing circuits with low-loss header
What is going on
Vitodens 200-W B2HB with DHW, one direct radiator circuit and two underfloor circuits with 3-way mixing valves. Total circuit flow is above the boiler maximum.
Check in this order
- Install a low-loss header (strongly recommended) and the Viessmann sensor for it.
- Install a mixing valve accessory kit for each underfloor circuit.
- Install boiler pump 20 and heating circuit pumps (28/20 per coding address 53).
- Pipe the DHW circulating pump S into the boiler.
Applies to: Vitodens 200-W B2HB
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Installation Instructions, p. 38. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.