System layout 5: radiator and mixed underfloor circuits with low-loss header
What is going on
One mixing-valve underfloor circuit and one radiator circuit without a mixing valve, with a low-loss header. Used when combined flow is above boiler maximum.
Check in this order
- Install the low-loss header and its Viessmann temperature sensor.
- Install the mixing valve accessory kit on the underfloor circuit.
- Pipe the DHW circulating pump into the boiler.
- Confirm the heating circuit pump sizes and coding address 53 for the DHW recirculation pump.
Applies to: Mixed heating circuits with low-loss header and DHW
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HA installation manual, p. 37. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.