Viessmann · Boiler troubleshooting

System Layout 5: mixing and non-mixing circuits with low-loss header

Vitodens 200-W B2HB

What is going on

Underfloor circuit with mixing valve and a radiator circuit without mixing valve, plus DHW. Total flow of the two circuits is greater than boiler maximum.

Check in this order

  1. Install a low-loss header, which is strongly recommended.
  2. Install the Viessmann sensor for the low-loss header.
  3. Connect the mixing valve kit for the underfloor circuit.
  4. Run the DHW circulating pump into the boiler as shown.

Applies to: Mixed and non-mixed circuits

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W, B2HB technical data manual, p. 38. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.