System Layout 4: radiator circuit plus underfloor mixing circuit
What is going on
Vitodens 200-W B2HB with DHW, one direct radiator circuit and one underfloor circuit with 3-way mixing valve.
Check in this order
- Make sure radiator circuit output flow is at least 30% greater than the underfloor circuit flow.
- Keep the total flow of both circuits below the boiler maximum on page 31.
- Use a low-loss header if flow exceeds page 31 values or is unknown (strongly recommended).
- Install the accessory kit for a heating circuit with mixing valve.
- Pipe the DHW circulating pump P into the boiler.
Applies to: Vitodens 200-W B2HB
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Installation Instructions, p. 36. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.