System layout 3: underfloor circuit with system separation

Vitodens 200-W

What is going on

Underfloor heating (low-temperature) circuit with a 3-way mixing valve and a plate heat exchanger for system separation, plus DHW. Needed when using non-oxygen-barrier tubing. Secondary-side components must be corrosion-resistant.

Check in this order

  1. Install a plate heat exchanger for system separation.
  2. Install the mixing valve accessory kit and its temperature sensor.
  3. Size the field pump carefully. An undersized pump can cause short-cycling.
  4. Use a low-loss header and boiler pump, which Viessmann strongly recommends here.
  5. Pipe the DHW circulating pump into the boiler.

Applies to: Underfloor heating with mixing valve and DHW

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HA installation manual, p. 35. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.