System layout 3: radiator circuit plus underfloor circuit with mixing valve
What is going on
Direct radiator circuit and a low-temperature underfloor circuit with 3-way mixing valve, plus DHW.
Check in this order
- Connect the radiator circuit directly to the boiler.
- Install the underfloor circuit with the mixing valve accessory kit and mixing valve sensor.
- Install the boiler pump, DHW storage tank, DHW sensor and DHW pumps.
- Install the expansion tank and relief valves.
Applies to: Vitocrossal 300 CU3A
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocrossal 300 CU3A technical data manual, p. 22. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.