System layout 2: DHW storage tank with low-loss header

Vitodens 100-W WB1B

What is going on

Layout with DHW storage tank, low-loss header and one heating circuit, controlled by an external boiler/DHW controller.

Check in this order

  1. Install the external boiler/DHW controller (field supplied) and DHW tank temperature aquastat or sensor.
  2. Install the low-loss header between boiler and heating circuit.
  3. Install the primary pump so it pumps into the boiler.
  4. Install the DHW circulating pump and the TPV on the DHW tank as shown.
  5. Install the air vent, PRV and expansion tank as shown.

Applies to: Vitodens 100-W WB1B 26 and 35

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W, WB1B CombiPlus Installation & Service Instructions, p. 39. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.