Viessmann · Boiler troubleshooting
Stand-alone DHW tank temperature sensor installation
What is going on
Needed only when a stand-alone DHW storage tank is used. Viessmann Vitocell 100 and 300 tanks have a sensor well.
Check in this order
- For Vitocell 100 or 300 tanks, locate the DHW sensor well and install the DHW temperature sensor following the tank instructions.
- If a non-Viessmann tank is used, verify with the tank manufacturer that the Viessmann DHW sensor will work with it.
- Install a temperature tempering valve in the DHW supply line (strongly recommended by Viessmann).
- Refer to the Service Instructions for system coding.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB installation manual, p. 21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.