Viessmann · Boiler troubleshooting
Setting heating circuit time program (switching times)
What is going on
Heating must be selected for the circuit, and normal and reduced temperatures must be set first. Up to four time cycles per day can be programmed, each changing between normal and reduced room temperature. With no cycles set, the circuit runs at reduced temperature all day. The factory sets time cycle 1 from 06:00 to 22:00 h on every weekday. Allow time for the house to reach the set temperature before the cycle starts.
Check in this order
- Make sure heating is selected for the circuit.
- Press the time program key ur.
- Press the day key to select all weekdays (arrows flash under all days) for identical cycles, or one weekday (one arrow flashes) for individual cycles.
- Confirm; time cycle 1 is shown.
- To skip a cycle, press the skip key; otherwise confirm.
- Set the cycle start time with the up/down keys and confirm.
- Set the cycle end time with the up/down keys and confirm.
- Repeat for cycles 2 to 4 as needed, then exit.
- To delete a cycle, press ur, step to the end time to delete, step until the end time shows the blank value, then confirm until the supply temperature shows again.
- To end programming early, press ur again.
Applies to: Vitotronic 200-H heating circuit time program
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 200-H operating instructions, pp. 9-10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.