Set the same space heating cycles for every day of the week
What is going on
The time program has four heating cycles. Default is cycle 1 from 06:00 to 22:00 every day, with normal room temperature during that time. Allow for the reaction time of the heating system when choosing start and end times.
Check in this order
- Open the flip-down cover of the remote control.
- Select 'Time Prog. Heating' and wait for the screen to appear.
- Select 'Heating Cycle 1' and then 'Heating Cycle 1 On'.
- Set the start time with the up/down keys and confirm; the display changes to 'Heating Cycle 1 Off'.
- Set the end time with the up/down keys and confirm; the display changes to 'Heating Cycle 2 On'.
- Set start and end times for cycles 2 to 4 the same way.
- Close the cover.
- To skip a cycle, press the skip key. To leave early, press the exit key.
Applies to: Vitotrol 300 remote control, space heating time program
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotrol 300 operating instructions, p. 12. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.