Viessmann · Boiler troubleshooting

Set individual space heating cycles for each day of the week

Vitotrol 300

What is going on

Each weekday can have its own heating cycles, up to four per day.

Check in this order

  1. Open the flip-down cover of the remote control.
  2. Select 'Time Prog. Heating' and wait for the screen to appear.
  3. Use the up/down keys to select the weekday to change.
  4. Select 'Heating Cycle 1' and then 'Heating Cycle 1 On'.
  5. Set the start time and confirm; the display changes to 'Heating Cycle 1 Off'.
  6. Set the end time and confirm; the display changes to 'Heating Cycle 2 On'.
  7. Set cycles 2 to 4 the same way.
  8. Close the cover.
  9. To skip a cycle, press the skip key. To leave early, press the exit key.

Applies to: Vitotrol 300 remote control, space heating time program

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotrol 300 operating instructions, p. 13. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.