Viessmann · Boiler troubleshooting
Set individual DHW cycles for each day of the week
What is going on
Each weekday can have its own DHW cycles, up to four per day.
Check in this order
- Open the flip-down cover of the remote control.
- Select 'Time Prog. DHW' and wait for the screen to appear.
- Select 'Individual?' and confirm.
- Use the up/down keys to select the weekday.
- Select 'DHW Heating Cycle 1' and then 'DHW Heating Cycle 1 On'.
- Set the start time and confirm; the display changes to 'DHW Heating Cycle 1 Off'.
- Set the end time and confirm; the display changes to 'DHW Heating Cycle 2 On'.
- Set cycles 2 to 4 the same way.
- Close the cover.
- To skip a cycle, press the skip key. To leave early, press the exit key.
Applies to: Vitotrol 300 remote control, DHW time program
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotrol 300 operating instructions, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.