Viessmann · Boiler troubleshooting

Routing and securing field connecting cables

Vitodens 200-W B2HA

What is going on

Cable routing rules for low-voltage and 120 V connections inside the control unit.

Check in this order

  1. Make sure cable temperature ratings are not exceeded anywhere along the run.
  2. Keep cables away from hot components, because contact will damage them.
  3. For larger cross-sections up to 9/16 in (about 14 mm), remove the existing cable grommet.
  4. Secure the power cable with the cable grommet fitted in the lower (black) casing section.
  5. Route each connecting cable to its area and secure it to the control base at the existing strain reliefs.

Applies to: Vitodens 200-W B2HA 80 to 100, 285 to 352

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HA 80 to 100, 285 to 352 Installation Instructions, p. 24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.