Viessmann · Boiler troubleshooting

Routine cleaning and maintenance

Vitodens 100-W B1HE/B1KE

What is going on

Maintenance intervals from the owner guide. Only qualified or authorised contractors should carry out internal work.

Check in this order

  1. Clean the boiler annually, since contamination raises flue gas temperature and energy losses.
  2. Clean the operating unit surface with a microfiber cloth and a non-scouring domestic cleaner.
  3. Have the DHW tank and its connections cleaned by a qualified contractor no later than 2 years after commissioning, then as required.
  4. Check the temperature and pressure relief valve every six months by venting it. Water may drip during heat-up.
  5. Do not close the safety valve. Overpressure can cause damage.
  6. For a potable water filter replace the element every six months on non-back-flushing filters, with a visual check every two months. On back-flushing filters, back flush every two months.
  7. Have the system serviced by an authorised contractor at least every 2 years.

Applies to: Vitodens 100-W B1HE/B1KE

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W B1HE/B1KE operating instructions, p. 31. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.