Viessmann · Boiler troubleshooting
Rooms too cold
What is going on
Work through these causes in order. The control unit may be off, misset, or faulted, or the mixer motor may be stuck.
Likely causes
- Heating circuit is switched off
- Power disconnect switched off
- Fuse or breaker tripped inside electrical panel
- Control unit settings incorrect (heating circuit on, room temperature, time, heating curve)
- Control unit fault (fault symbol U flashes)
- Mixer motor faulty
Check in this order
- Press the ON/OFF button to turn the control unit on (see start-up).
- Switch on the power disconnect if one is installed outside the boiler room.
- Check the fuse or breaker inside the electrical panel; if it has tripped, notify the heating contractor.
- Check heating circuit is on, then the room temperature, time program and heating curve settings, and correct as needed.
- If the fault symbol U flashes, scan the fault code and notify the heating contractor.
- If the mixer motor is faulty unlock motor lever A and operate mixer lever B by hand, then notify the heating contractor.
Applies to: Vitotronic 200-H heating circuit
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 200-H operating instructions, p. 15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.