Viessmann · Boiler troubleshooting
Rooms cold while the burner is running
What is going on
The burner runs but the rooms stay cold, even with a low outdoor temperature.
Likely causes
- Time incorrectly set
- Heating program w or 9 selected
- DHW priority active on a tank system
- On/off switch on the mixing valve motor is OFF
- Heating curve setting incorrect
- Control unit incorrectly programmed
Check in this order
- Set the correct time on page 20.
- Set heating program rw (page 6) if program w or 9 is selected.
- On tank systems, wait until the DHW tank heats up (w goes off in the display).
- Turn the mixing valve motor on/off switch to I ON.
- Check and correct the heating curve on page 21.
- Check and correct the temperature settings (page 8), time program (page 12) and heating program (page 7).
Applies to: Room heating
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 300 GW2 operating instructions, p. 29. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.