Viessmann · Boiler troubleshooting

Rooms cold while burner is operating (single-boiler)

Vitotronic 100, GC1

What is going on

Burner runs but the rooms do not heat properly.

Likely causes

  • Heating program w or 9 is set (its button is lit)
  • DHW priority: boiler is heating the DHW tank first
  • Room temperature too low at low outdoor temperature because of incorrect control settings
  • Rooms cold during the day but warm at night because of incorrect control settings

Check in this order

  1. If program w or 9 is set, set program rw (see page 6).
  2. If the DHW tank is being heated, wait until it has reached temperature.
  3. Check and correct the temperature settings (page 9) and the heating program (page 6).

Applies to: Single-boiler systems

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 100, GC1 operating instructions, p. 14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.