Viessmann · Boiler troubleshooting

Rooms are too cold

Vitotronic 200Vitotronic 300-K

What is going on

Heating is off or the control or remote settings are wrong, or there is no fuel.

Likely causes

  • Heating system switched off at a control unit or mains isolator.
  • Fuse or MCB tripped.
  • Control unit or remote control set wrong.
  • DHW priority active, or DHW tank still heating.
  • Slab curing function active (not used).
  • No fuel: low oil or LPG, or gas shut-off closed.
  • Fault active on the boiler.

Check in this order

  1. Set the ON/OFF switches at all control units to ON.
  2. Turn on the mains isolator if installed.
  3. Check the fuse/MCB and reset or replace if needed.
  4. On the Vitotronic 200, make sure the heating symbol is set.
  5. On the 300-K, check heating and DHW mode, room temperature, time, time program and heating curve.
  6. Check the remote control settings if fitted.
  7. Check fuel reserves and reorder if needed, or open the gas shut-off valve.
  8. If a fault shows, scan and note the code, acknowledge it, and call the heating contractor.

Applies to: Vitotronic 200 and 300-K

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 200 and 300-K Operating Instructions, p. 35. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.