Viessmann · Boiler troubleshooting
Reversing the mixing valve motor rotation
What is going on
Used when the mixing valve must turn the other way for the installation. The motor plug is turned 180° to reverse rotation.
Check in this order
- Remove the cover of the mixing valve motor.
- Pull out the 3-pole plug A and reinsert it turned 180°.
- Run the relay test on the control unit and confirm the valve moves to Open and Closed as expected.
Applies to: Mixing valve motor
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 200-H installation and service instructions, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.