Remote telephone switch wiring
What is going on
The remote switch must be a dry, potential-free contact. Applying voltage to it will damage the controller.
Check in this order
- Wire a dry, potential-free contact from the switch, relay or contact.
- Run the field wiring from the contact to the controller sub-base.
- Connect the wires to terminals 3 and 4.
- Confirm the contact is potential free before connecting. Do not apply voltage.
Applies to: Versatronik COMO OT remote switch input (terminals 3+4)
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Versatronik COMO OT manual, p. 12. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.